Performance Analysis of Inserted Resonators in Microstrip Array Antenna for Biomedical Applications: Enhancing Bandwidth and Resonance through Resonator Engineering

Biomedical radar and wireless sensing technologies require compact antennas that provide adequate bandwidth, stable resonance characteristics, and sufficient gain for reliable physiological signal detection. Microstrip patch antennas have become attractive candidates because of their low profile, ease of fabrication, simple structure, and compatibility with microwave integrated circuits. Nevertheless, conventional microstrip antennas often suffer from relatively narrow bandwidth and limited gain, restricting their performance in demanding biomedical applications. The reviewed study investigates how strategically inserting resonators and defective ground structure (DGS) slots into a 2×1 rectangular microstrip array antenna can improve antenna performance while maintaining a compact design. Using electromagnetic simulations performed in FEKO, the researchers systematically evaluate resonator placement and slot configurations to optimize resonance frequency, reflection coefficient, bandwidth, voltage standing wave ratio (VSWR), and realized gain for operation within the 5–6 GHz Industrial, Scientific, and Medical (ISM) band. This review summarizes the study's methodology, principal findings, scientific contributions, practical implications, and future research opportunities.

Bibliographic Information

Item Information
Article Title Performance analysis of inserted resonators in microstrip array antenna for biomedical applications
Authors Cing Nuam Man; Thanda Win; Hla Myo Tun; Mya Mya Aye
Journal Journal of Engineering Researcher and Lecturer
Volume 4
Issue 1
Publication Year 2025
Pages 9–21
DOI https://doi.org/10.58712/jerel.v4i1.177
Publisher Researcher and Lecturer Society
License Creative Commons Attribution 4.0 International (CC BY 4.0)
ISSN ISSN 2963-7511
Keywords microstrip patch array antenna; FR4 substrate; resonance frequency; resonator

1. Research Background

Reliable monitoring of human vital signs has become increasingly important in modern healthcare, particularly for applications involving respiratory monitoring, non-contact sensing, medical imaging, and wearable healthcare systems. Radar-based biomedical monitoring systems depend heavily on antenna performance because antennas are responsible for transmitting and receiving electromagnetic signals that carry physiological information. Consequently, antenna bandwidth, resonance stability, radiation characteristics, and gain directly influence measurement accuracy and overall system reliability.

Microstrip patch antennas have gained widespread attention for biomedical applications because they offer several practical advantages, including compact dimensions, lightweight construction, relatively low manufacturing cost, ease of fabrication, low-profile geometry, and straightforward integration with microwave integrated circuits. These characteristics make them attractive for portable and non-contact biomedical devices operating in the Industrial, Scientific, and Medical (ISM) frequency band.

Despite these advantages, conventional microstrip patch antennas generally exhibit relatively narrow bandwidth and limited gain. These limitations reduce their suitability for biomedical radar applications that require broader operating bandwidths and stronger directional radiation characteristics. Previous engineering studies have explored several improvement techniques, including increasing substrate thickness, employing high-permittivity substrates, modifying ground structures, introducing slots into the patch or ground plane, and developing array antenna configurations.

The reviewed study investigates another design strategy by combining a 2×1 rectangular microstrip array with inserted resonators positioned between antenna elements and multiple slots incorporated into the ground plane through the Defected Ground Structure (DGS) approach. Rather than redesigning the entire antenna geometry, the research focuses on determining how resonator placement and slot positioning influence resonance frequency, impedance matching, bandwidth, gain, and overall antenna performance through systematic electromagnetic simulation.

The antenna is designed using an FR4 substrate with a dielectric constant of 4.4 and targets operation within the 5–6 GHz frequency range. Besides biomedical sensing, the operating frequency also supports applications associated with the ISM band, including Wi-Fi, Bluetooth, low-power wireless communication, WiFi 6E, low-noise amplifier systems, robotic technologies, and selected 5G-related applications.


2. Research Objective

  • To design a compact 2×1 rectangular microstrip array antenna suitable for biomedical applications operating within the 5–6 GHz frequency range.
  • To investigate how inserted resonators positioned between adjacent antenna elements influence resonance frequency, impedance characteristics, and antenna gain.
  • To evaluate the effect of multiple ground-plane slots implemented using the Defected Ground Structure (DGS) technique on antenna bandwidth and overall electromagnetic performance.
  • To analyze different resonator and slot positions through electromagnetic simulations performed using FEKO software.
  • To identify resonator configurations capable of improving reflection coefficient, Voltage Standing Wave Ratio (VSWR), realized gain, and bandwidth while maintaining a compact antenna structure.
  • To compare the simulated antenna performance obtained from different resonator configurations and determine the most effective arrangement for biomedical sensing applications.

3. Why This Research Matters

  • Supports non-contact biomedical monitoring. Improved antenna performance contributes to more reliable respiratory monitoring and other biomedical radar applications.
  • Addresses the bandwidth limitation of conventional microstrip antennas. The study investigates practical techniques for widening bandwidth without substantially increasing antenna size.
  • Enhances compact antenna design. The proposed design achieves improved electrical performance while maintaining dimensions suitable for portable biomedical devices.
  • Demonstrates the effectiveness of resonator engineering. Systematic adjustment of resonator positions provides valuable insight into resonance control and impedance matching.
  • Applies the Defected Ground Structure (DGS) concept. Ground-plane slot modifications are evaluated as an effective approach for bandwidth enhancement and mutual coupling reduction.
  • Expands applications beyond healthcare. The antenna configuration is also suitable for ISM-band wireless communication, Bluetooth, Wi-Fi, WiFi 6E, robotic systems, and selected low-power communication technologies.
  • Provides practical engineering guidance. The study offers antenna designers a systematic methodology for evaluating resonator placement using numerical electromagnetic simulation.

4. Research Methodology

The study employed a quantitative engineering design approach based entirely on numerical electromagnetic simulation. Rather than fabricating multiple antenna prototypes, the researchers designed, modified, and evaluated several antenna configurations using FEKO electromagnetic simulation software. The investigation focused on understanding how inserted resonators and defective ground structure (DGS) slots affect resonance frequency, impedance matching, bandwidth, reflection coefficient, Voltage Standing Wave Ratio (VSWR), and realized gain.

Research Design

  • Simulation-based antenna design and performance evaluation.
  • Parametric investigation of resonator placement and ground-slot configurations.
  • Comparative analysis of multiple antenna configurations.
  • Electromagnetic performance assessment using FEKO software.

Antenna Configuration

The antenna consists of a rectangular inset-feed microstrip patch array constructed on an FR4 substrate with a dielectric constant of 4.4 and a substrate thickness of 1.6 mm. Two identical rectangular microstrip patches were connected to form a 2×1 array configuration. The overall antenna dimensions were approximately 26 mm × 50 mm × 1.6 mm, while each individual patch measured approximately 11.7 mm × 15.7 mm × 1.6 mm.

Design Procedure

The research was conducted through four sequential design stages. Initially, a single inset-feed rectangular microstrip antenna was designed using conventional design equations. The second stage combined two identical patches into a 2×1 corporate-feed array to improve antenna gain. The third stage introduced a narrow rectangular resonator between the two radiating elements to improve resonance characteristics and reduce mutual coupling. Finally, four slots were incorporated into the ground plane using the Defected Ground Structure (DGS) technique to enhance bandwidth and optimize overall antenna performance.

Simulation Parameters

The antenna was designed to operate within the 5–6 GHz frequency range centered near 5.8 GHz. Standard microstrip antenna design equations were employed to determine patch width, patch length, substrate dimensions, inset-feed position, feed-line width, inset-feed gap, and transmission-line dimensions. The antenna geometry was subsequently optimized through parametric simulations.

Resonator Investigation

The inserted resonator located between the two patch elements had fixed dimensions of 11.2 mm × 0.36 mm. While the resonator dimensions remained constant, the researchers systematically modified the positions of four additional slots located on the ground plane. Seven different resonator-slot configurations were investigated by adjusting slot positions relative to the antenna center while maintaining identical slot dimensions of 12 mm × 1.2 mm.

Performance Evaluation

Each antenna configuration was evaluated using several standard electromagnetic performance indicators, including resonance frequency, reflection coefficient (S11), bandwidth, Voltage Standing Wave Ratio (VSWR), realized gain, radiation pattern, and far-field characteristics. Current distributions on both the front and back sides of the antenna were also analyzed to understand the electromagnetic mechanisms responsible for performance improvements.


5. Key Findings

Inserted Resonators Successfully Improved Antenna Performance

The simulation results demonstrate that inserting a resonator between the two microstrip patch elements effectively modifies antenna performance. Different resonator positions produced measurable changes in resonance frequency, reflection coefficient, bandwidth, VSWR, and realized gain, confirming that resonator placement is an important design parameter.

Bandwidth Enhancement Was Achieved Through Ground Slots

The incorporation of four slots into the ground plane using the Defected Ground Structure (DGS) approach successfully increased antenna bandwidth compared with the basic array configuration. The modified ground structure also contributed to improved impedance matching and better resonance behavior.

Resonator Position Influenced Resonance Frequency

Adjusting the positions of the ground slots while maintaining a fixed resonator size shifted the resonance frequency between approximately 5.78 GHz and 6.04 GHz. This demonstrates that careful placement of resonator-related structures provides an effective mechanism for frequency tuning without significantly altering the overall antenna dimensions.

Improved Reflection Coefficient

Several resonator configurations produced improved reflection coefficients compared with the basic array antenna. The best-performing configurations achieved substantially lower reflection coefficients, indicating improved impedance matching and reduced reflected power at the operating frequency.

Low VSWR Values Demonstrated Good Impedance Matching

The optimized antenna configurations produced VSWR values close to unity, indicating effective impedance matching between the transmission line and the radiating structure. Such performance is desirable for efficient power transfer in biomedical sensing applications.

Realized Gain Increased After Resonator Integration

The optimized resonator arrangements produced realized gains exceeding 7 dBi. Depending on resonator placement, realized gain ranged approximately from 7.2 dBi to nearly 7.9 dBi, demonstrating the effectiveness of the resonator-assisted array design.

Current Distribution Explained Performance Improvements

Current-distribution analysis revealed that the inserted resonator modified electromagnetic current flow between adjacent patches. Meanwhile, the ground-plane slots altered the magnetic field distribution beneath the antenna, contributing to bandwidth enhancement and resonance adjustment.

Compact Dimensions Were Maintained

Despite incorporating additional resonators and ground slots, the proposed antenna retained a compact overall size suitable for biomedical devices and other portable wireless communication systems operating within the ISM frequency band.


6. Scientific Contribution

  • Introduces a resonator-assisted microstrip array configuration. The study demonstrates how inserted resonators positioned between adjacent patch elements can improve multiple antenna performance parameters simultaneously.
  • Combines resonator engineering with Defected Ground Structure (DGS). The integration of resonators and ground-plane slots provides a practical design strategy for improving bandwidth and resonance characteristics.
  • Provides systematic parametric evaluation. Multiple resonator positions were investigated to determine how geometric placement influences antenna performance.
  • Demonstrates compact antenna optimization. Performance improvements were achieved without substantially increasing antenna size, an important consideration for biomedical devices.
  • Strengthens understanding of electromagnetic behavior. Current-distribution analysis explains the physical mechanisms responsible for bandwidth enhancement and resonance control.
  • Expands practical design knowledge for ISM-band antennas. The findings contribute useful engineering guidance for designers developing compact antennas for biomedical and wireless communication applications.

7. Industrial Implications

  • Improves biomedical sensing devices. The proposed antenna design offers enhanced bandwidth and gain, making it suitable for non-contact respiratory monitoring and other biomedical radar applications that require reliable electromagnetic performance.
  • Supports compact wireless medical equipment. Maintaining a relatively small antenna size while improving electrical characteristics makes the design attractive for portable and wearable healthcare technologies.
  • Enhances ISM-band communication systems. Operating within the 5–6 GHz frequency range enables potential implementation in Industrial, Scientific, and Medical (ISM) wireless devices, including Wi-Fi, Bluetooth, and WiFi 6E applications.
  • Provides practical guidance for antenna designers. The systematic evaluation of resonator and slot positions offers engineers a straightforward methodology for optimizing microstrip array antennas without extensive structural redesign.
  • Supports low-cost antenna manufacturing. The antenna is fabricated on an FR4 substrate, a widely available and economical material that facilitates practical manufacturing for commercial applications.
  • Applicable to emerging wireless technologies. Besides biomedical sensing, the proposed antenna architecture may support robotic communication systems, low-noise amplifier (LNA) systems, selected 5G-related applications, and other short-range wireless devices operating within the designated frequency band.

8. Research Limitations

  • The investigation is entirely based on numerical simulations performed using FEKO software. Experimental fabrication and laboratory measurements were not reported.
  • The study evaluates only a limited number of resonator and slot configurations. Additional geometric variations may further improve antenna performance.
  • The antenna was designed specifically for operation within the 5–6 GHz frequency range. Its performance outside this frequency range was not investigated.
  • Only one substrate material (FR4 with dielectric constant 4.4) was considered. Alternative substrate materials were beyond the scope of the investigation.
  • The research focuses primarily on electromagnetic characteristics, including resonance frequency, reflection coefficient, bandwidth, VSWR, radiation pattern, and realized gain. Long-term reliability, fabrication tolerances, and environmental influences were not examined.
  • The biomedical application is evaluated from an antenna performance perspective only. Complete biomedical system validation involving physiological signal acquisition was not included in this study.

9. Future Research Opportunities

  • Fabricate and experimentally validate the proposed antenna to compare measured results with the numerical simulations.
  • Investigate alternative resonator geometries and dimensions to further improve impedance matching, gain, and bandwidth.
  • Evaluate additional Defected Ground Structure (DGS) configurations to determine their influence on mutual coupling and radiation performance.
  • Study the use of alternative dielectric substrates with different permittivity and thickness to optimize antenna miniaturization and efficiency.
  • Extend the antenna design for larger array configurations capable of achieving higher directional gain for advanced biomedical radar systems.
  • Investigate Specific Absorption Rate (SAR) performance using realistic multilayer human tissue models for biomedical safety assessment.
  • Evaluate antenna performance under practical biomedical operating conditions, including respiratory monitoring, motion detection, and wearable healthcare scenarios.
  • Compare the proposed resonator-assisted approach with alternative bandwidth-enhancement techniques such as metamaterials, electromagnetic bandgap structures, parasitic elements, and fractal geometries.
  • Develop optimization frameworks using artificial intelligence or evolutionary algorithms to automatically determine optimal resonator and slot positions.
  • Investigate the integration of the proposed antenna with complete biomedical radar systems for real-time vital-sign monitoring and healthcare Internet of Things (IoT) applications.

10. Potential for Public Policy Citation

Although this study primarily focuses on antenna engineering, its findings have potential relevance for public policies supporting digital healthcare, biomedical engineering innovation, and advanced wireless communication technologies. Reliable non-contact physiological monitoring systems can contribute to healthcare modernization by enabling remote patient observation and continuous health monitoring.

The compact antenna design proposed in this research may also support broader initiatives promoting medical technology development, telemedicine, smart healthcare infrastructure, and wireless sensing technologies. Furthermore, the engineering methodology demonstrates how simulation-driven design can accelerate technological innovation while reducing development costs.

Consequently, the study may serve as a useful technical reference for researchers, healthcare technology developers, engineering standard organizations, and government agencies supporting biomedical device innovation and next-generation wireless communication systems.


11. Who Should Read This Paper?

  • Researchers specializing in microstrip antenna design and microwave engineering.
  • Biomedical engineers developing non-contact healthcare monitoring systems.
  • Engineers working on radar-based respiratory monitoring technologies.
  • Wireless communication researchers interested in compact ISM-band antenna design.
  • Graduate students studying antennas, electromagnetics, microwave engineering, and biomedical electronics.
  • Researchers investigating Defected Ground Structure (DGS) techniques and resonator-assisted antenna optimization.
  • Engineers designing IoT healthcare devices and wearable biomedical systems.
  • Industrial researchers involved in RF communication systems, wireless sensing technologies, and compact antenna development.

12. Frequently Asked Questions (FAQ)

What is the primary objective of this research?

The study aims to improve the performance of a compact 2×1 rectangular microstrip array antenna by introducing inserted resonators between adjacent patch elements and slots in the ground plane. The objective is to enhance bandwidth, optimize resonance frequency, improve impedance matching, and increase realized gain for biomedical applications operating in the 5–6 GHz frequency range.

Why are inserted resonators used in the antenna?

The inserted resonators modify the electromagnetic current distribution between the two radiating patches. Their placement influences resonance frequency, reflection coefficient, gain, and impedance matching, enabling the antenna to achieve improved electrical performance without substantially increasing its physical dimensions.

What is the function of the Defected Ground Structure (DGS)?

The Defected Ground Structure introduces slots into the antenna's ground plane to alter current flow and electromagnetic field distribution. In this study, the DGS technique primarily improves bandwidth, assists resonance tuning, and contributes to better overall antenna performance.

Which software was used in the research?

All antenna designs and performance evaluations were carried out using FEKO electromagnetic simulation software.

What operating frequency does the antenna target?

The antenna is designed to operate within the 5–6 GHz frequency range, centered near 5.8 GHz, making it suitable for Industrial, Scientific, and Medical (ISM) band applications.

Besides biomedical applications, where else could this antenna be used?

According to the study, the antenna may also be suitable for Wi-Fi, Bluetooth, WiFi 6E, robotic communication systems, low-noise amplifier (LNA) applications, selected 5G-related technologies, and other short-range wireless communication systems operating within the ISM frequency band.

Was the antenna experimentally validated?

No. The investigation reported in this paper is based on numerical electromagnetic simulations. Experimental fabrication and laboratory validation were not included.


13. Final Thoughts

This study presents a systematic investigation into the use of inserted resonators and Defected Ground Structure (DGS) techniques for improving the performance of compact microstrip array antennas intended for biomedical applications. Rather than relying solely on conventional antenna geometries, the researchers demonstrate how relatively simple structural modifications can significantly influence resonance characteristics, bandwidth, impedance matching, and realized gain.

A notable strength of the work lies in its structured design methodology. Beginning with a conventional single inset-feed rectangular patch, the research progressively develops a 2×1 array configuration before introducing resonators and ground-plane slots. This sequential approach clearly illustrates how each design modification contributes to overall antenna performance and provides valuable engineering insight into resonator-assisted antenna optimization.

Another important contribution is the detailed parametric evaluation of resonator positions. Rather than evaluating only a single design, the study systematically compares several resonator configurations, allowing readers to better understand the relationship between resonator placement and key electromagnetic parameters such as resonance frequency, reflection coefficient, bandwidth, VSWR, and realized gain.

Overall, this research offers a practical engineering reference for antenna designers, biomedical engineers, and wireless communication researchers interested in compact ISM-band antenna development. Although future experimental validation remains necessary, the numerical findings provide a solid foundation for further research on resonator-assisted microstrip array antennas for biomedical sensing and other wireless communication technologies.


14. Suggested Citations

UNP-Teknomekanik Style

C. N. Man, T. Win, H. M. Tun, and M. M. Aye, "Performance analysis of inserted resonators in microstrip array antenna for biomedical applications," Journal of Engineering Researcher and Lecturer, vol. 4, no. 1, pp. 9–21, 2025, https://doi.org/10.58712/jerel.v4i1.177.

APA 7th Edition

Man, C. N., Win, T., Tun, H. M., & Aye, M. M. (2025). Performance analysis of inserted resonators in microstrip array antenna for biomedical applications. Journal of Engineering Researcher and Lecturer, 4(1), 9–21. https://doi.org/10.58712/jerel.v4i1.177

IEEE

C. N. Man, T. Win, H. M. Tun, and M. M. Aye, "Performance analysis of inserted resonators in microstrip array antenna for biomedical applications," Journal of Engineering Researcher and Lecturer, vol. 4, no. 1, pp. 9–21, 2025, doi: 10.58712/jerel.v4i1.177.

Harvard

Man, C.N., Win, T., Tun, H.M. and Aye, M.M. (2025) 'Performance analysis of inserted resonators in microstrip array antenna for biomedical applications', Journal of Engineering Researcher and Lecturer, 4(1), pp. 9–21. doi:10.58712/jerel.v4i1.177.

Vancouver

Man CN, Win T, Tun HM, Aye MM. Performance analysis of inserted resonators in microstrip array antenna for biomedical applications. Journal of Engineering Researcher and Lecturer. 2025;4(1):9–21. doi:10.58712/jerel.v4i1.177.

Chicago Author–Date

Man, Cing Nuam, Thanda Win, Hla Myo Tun, and Mya Mya Aye. 2025. "Performance Analysis of Inserted Resonators in Microstrip Array Antenna for Biomedical Applications." Journal of Engineering Researcher and Lecturer 4 (1): 9–21. https://doi.org/10.58712/jerel.v4i1.177.

MLA 9th Edition

Man, Cing Nuam, et al. "Performance Analysis of Inserted Resonators in Microstrip Array Antenna for Biomedical Applications." Journal of Engineering Researcher and Lecturer, vol. 4, no. 1, 2025, pp. 9–21. Crossref, https://doi.org/10.58712/jerel.v4i1.177.


15. Editorial Note

This review has been prepared solely for educational and scholarly communication purposes. The scientific discussion presented above is based on the contents of the published research article and is intended to assist readers in understanding the study's objectives, methodology, findings, and engineering significance. Readers are strongly encouraged to consult, download, and cite the original publication whenever this research contributes to their own academic work, technical reports, or engineering projects. Proper citation of the original article ensures appropriate academic recognition for the authors and supports responsible scholarly communication.


SEO Meta Description

Comprehensive review of a resonator-assisted microstrip array antenna for biomedical applications, explaining how inserted resonators and defective ground structures improve bandwidth, resonance frequency, gain, and ISM-band antenna performance.


SEO Keywords

microstrip array antenna, biomedical antenna, inserted resonator, resonator antenna, defective ground structure, DGS antenna, FR4 substrate, ISM band antenna, biomedical radar, respiratory monitoring antenna, FEKO simulation, compact antenna, microstrip patch antenna, wireless biomedical sensor, antenna bandwidth enhancement

Comments